How is each lot of bacteriostatic water documented?

Match the vial to the record.

For Research Use Only. Not for Human Consumption.

Nexus bacteriostatic water is specified in 30 mL vials, supplied individually or in packs of 5, 10, and 50. The documentation record covers composition, sterility, and endotoxin testing. Verify the lot identifier and published certificate before purchase. For Research Use Only. Not for Human Consumption.

What is reviewed before a lot is released?

The release record connects the filled lot, analytical documentation, and packaged vial identifiers. Composition, sterility, and endotoxin records are reviewed against the applicable specifications before release.

What if a certificate is not yet published?

A pending field is not a test result. Request the matching lot documentation before purchase; do not substitute another lot’s certificate.

What water is the base of every vial?

More than 99% of each 30 mL vial is the base water. The rest is USP-grade benzyl alcohol at 0.9%. Whatever is in the base water is in the vial. Nothing later in the process takes it out.

Nexus starts from AQUAPure HYPER, a sterile water made by Aquabiliti in York, Pennsylvania, to the USP and European Pharmacopoeia monographs. Its endotoxin specification is a fifth of the compendial limit. It arrives sealed in a single-use, gamma-irradiated container. Every charge into a batch is weighed.

Base water, as received
Base water, as receivedSpecification
ProductAQUAPure HYPER (Aquabiliti), USP / EP grade
Endotoxin (USP <85>)≤ 0.05 EU/mL, retested after filling (compendial limit 0.25 EU/mL)
Total organic carbon (USP <643>)< 8.00 mg/L
Conductivity (USP <645>)≤ 5 µS/cm
Particulate matter (USP <788>)≤ 25 per mL ≥ 10 µm · ≤ 3 per mL ≥ 25 µm
Sterility (USP <71>)No growth
Residue on evaporation (EP)≤ 0.003%
Nitrates (EP)≤ 0.2 ppm
Oxidizable substances (EP)Pass
Base water, at generation
Base water, at generationSpecification
Conductivity, online≤ 0.06 µS/cm (compendial limit 1.3 µS/cm)
Total organic carbon≤ 20 ppb (compendial limit 500 ppb)
PurificationContinuous electrodeionization, no holding tank
Water grade at generationASTM Type 1A
Endotoxin monitoringWeekly, kinetic chromogenic assay (USP <85>). Results below the 0.01 EU/mL detection limit
Container, shelf life and materials
Container, shelf life and materialsSpecification
Container sterilizationRadiation, validated minimum 25 kGy (ISO 11137-1 / -2, VDmax25). 200 L validation bag: average bioburden 12.8 CFU across three lots, 10 of 10 sterility samples negative
Extractables (USP <1663>)21 days at 40 °C. No volatile or semi-volatile organics above 0.10 µg/mL. No metals above 0.01 µg/mL. Non-volatile compounds detected were identified and assessed
Shelf life12 months, real-time stability. Sterility, endotoxin, TOC, conductivity and particulates passed at 0, 3, 6, 9 and 12 months
MaterialsNo animal-origin materials. No solvents used or produced
Aquabiliti facilitiesISO 13485:2016 certified, USA

Aquabiliti specifications and study results for AQUAPure HYPER. Each finished lot is tested separately. Its results are on the lot certificate.

What does the current lot record show?

Lot NXW-2609-01, tested by Bioviridian. Certificate COA10452, issued 2026-10-14.

Bacteriostatic water lot NXW-2609-01 test results
TestResultMethod
IdentityBenzyl alcoholLC-MS/MS
Content0.9914%HPLC quantitation
Overall purity99.81%RP-HPLC (214 nm)
Endotoxin<0.05 EU/mLUSP <85>
pH7.04pH meter
Expiry2028-09-13
View the lot record and certificate